Automatic 12-Step Power Factor Improvement (PFI) Plant Panel
Quick Product Summary
- Model: PP-PFI-800KVAR
- Capacity: 100 kVAR - 1200 kVAR Automatic Compensation
- Standard: IEC 60831-1 & 2, IEC 61439-1
- Manufacture: Positive Power Gazipur
Technical Sales Inquiry:
Direct Phone: +880 1712-345678
Email: info@positivepowerbd.com
Engineering Overview & Scope
Industrial inductive loads such as induction motors, transformers, and welding sets cause poor power factor, leading to severe utility surcharge penalties. Positive Power’s Automatic Power Factor Improvement (PFI) panels automatically monitor and adjust reactive power compensation to maintain a system power factor above 0.98 at all times.
Key Engineering Advantages
- Microprocessor-based 12-step digital auto power factor controller
- Heavy-duty gas-filled self-healing metallized polypropylene capacitors
- 7% or 14% detuned harmonic filter reactors preventing harmonic resonance
- Special capacitor-duty switching contactors with inrush damping resistors
- Automatic thermostatic ventilation fan cooling system
Primary Industrial Applications
- ▪ Preventing Utility Low Power Factor Surcharges across all factories
- ▪ Spinning Mills, Weaving Units & Dyeing Factories
- ▪ Steel Rolling & Metal Fabrication Works
- ▪ Commercial Malls, Towers & Hospitals
Comprehensive Technical Specifications
Manufactured and rigorously tested according to international IEC standards and certified by BUET (Bangladesh University of Engineering and Technology).
| Technical Parameter | Engineering Specification |
|---|---|
| Reactive Power Capacity | 100 kVAR to 1200 kVAR |
| Steps Configuration | 6 / 8 / 12 / 16 Automatic Steps |
| Operating Voltage | 415 V / 440 V, 50 Hz |
| Detuned Reactor | 7% (189 Hz) or 14% (134 Hz) copper-wound |
| Controller Display | Digital display showing cos φ, voltage, current, THD-V, THD-I |
🔬 Routine & Type Testing
100% factory routine tests including Megger insulation, dielectric breakdown, turns ratio, load/no-load losses, and temperature rise per IEC 60076.
🏛️ BUET Tested & Endorsed
Independently verified and type-tested through Bangladesh University of Engineering and Technology (BUET) electrical testing laboratories.
🛡️ 18-Month Warranty & Support
Full warranty backing with 24/7 on-site emergency technical support, genuine OEM spare parts, and annual preventive maintenance contracts.
Request a Quotation for Automatic 12-Step Power Factor Improvement (PFI) Plant Panel
Please enter your project capacity requirements and site details below. Our senior power systems engineering team will provide a comprehensive technical and commercial proposal within 24 hours.
Related Equipment in Distribution Board
Main Distribution Board (MDB) with Drawout ACB
Custom-fabricated low-voltage Main Distribution Board (MDB) with motorized drawout Air Circuit Breaker and 99.9%…
Sub-Distribution Board (SDB) with Automatic Phase Selector
Compact floor distribution board with MCCB incomer, 10kA MCB branch protection, and automatic phase…