Cast Resin Dry-Type Fire-Resistant Transformer

Dry Type Transformer Model: PP-CRT-1000 Standard: IEC 60076-11, DIN 42523, EN 60076-11
⚡

PP-CRT-1000

250 kVA - 3150 kVA (Up to 33kV)

Quick Product Summary
  • Model: PP-CRT-1000
  • Capacity: 250 kVA - 3150 kVA (Up to 33kV)
  • Standard: IEC 60076-11, DIN 42523, EN 60076-11
  • Manufacture: Positive Power Gazipur

Technical Sales Inquiry:

Direct Phone: +880 1712-345678
Email: info@positivepowerbd.com

Engineering Overview & Scope

Positive Power Cast Resin Dry-Type Transformers eliminate flammable oil entirely, utilizing pure epoxy resin vacuum casting with quartz flour filling. This delivers outstanding dielectric insulation, self-extinguishing flame resistance, and moisture impermeability.

Classified under Environmental Class E2, Climatic Class C2, and Fire Behavior Class F1 per IEC 60076-11, it is safe for installation inside densely occupied spaces without requiring fire suppression blast walls or oil containment pits.

Key Engineering Advantages

  • Complete fire resistance with self-extinguishing epoxy resin casting
  • Zero oil leak hazard and zero toxic gas emission
  • Class F (155°C) or Class H (180°C) high-temperature insulation
  • Equipped with cross-flow forced cooling fans for +40% emergency overload capacity
  • Digital PT100 temperature monitoring controller

Primary Industrial Applications

  • ▪ Commercial High-Rise Buildings & Shopping Malls
  • ▪ Underground Metro Rail Substations & Airports
  • ▪ Data Centers & Telecom Central Switching Offices
  • ▪ Cleanrooms & Pharmaceutical Packaging Facilities
Engineering Data

Comprehensive Technical Specifications

Manufactured and rigorously tested according to international IEC standards and certified by BUET (Bangladesh University of Engineering and Technology).

Technical Parameter Engineering Specification
Rated Capacity 250 kVA to 3150 kVA
Rated Voltage 11 kV or 33 kV / 0.415 kV
Insulation Class Class F (155°C) / Class H (180°C)
Partial Discharge < 10 pC (Industry benchmark)
Environmental / Fire Class E2, C2, F1 (IEC 60076-11 Certified)
Enclosure Ingress Protection IP00 (Bare) up to IP31 / IP44 (Sheet Metal Enclosure)
Overload Capability Up to 140% continuous with forced air ventilation

🔬 Routine & Type Testing

100% factory routine tests including Megger insulation, dielectric breakdown, turns ratio, load/no-load losses, and temperature rise per IEC 60076.

🏛️ BUET Tested & Endorsed

Independently verified and type-tested through Bangladesh University of Engineering and Technology (BUET) electrical testing laboratories.

🛡️ 18-Month Warranty & Support

Full warranty backing with 24/7 on-site emergency technical support, genuine OEM spare parts, and annual preventive maintenance contracts.

Fast Quote Request

Request a Quotation for Cast Resin Dry-Type Fire-Resistant Transformer

Please enter your project capacity requirements and site details below. Our senior power systems engineering team will provide a comprehensive technical and commercial proposal within 24 hours.

Request a Quote & Contact Form
Catalog Exploration

Related Equipment in Dry Type Transformer

⚡
PP-VPI-630

VPI (Vacuum Pressure Impregnated) Dry-Type Transformer

Heavy-duty VPI dry transformer utilizing high-grade polyester resin impregnation for superior resistance to electrical…

160 kVA - 2000 kVA View Specs →